Lucent Product Catalog, 1 of 5
| Page 1 of 5 [ Next Page ] | |||
| SKU 0 | Description | Action | |
|---|---|---|---|
| 11102 | CBX 500 DS3 FRAME IO |
| |
| 11107A | 4 Port 10/100 Ethernet Processor Card (Memory Enhanced) |
| |
| 11504 | GX-550 13 SLOT CHASSIS |
| |
| 11505 | GX550 SWITCH FAB ADPTR |
| |
| 11702 | GX-250 13 SLOT CHASSIS |
| |
| P15-1SBRI | Pipeline 15 with an 120V AC adapter. |
| |
| P15-1UBRI | Pipeline 15 with an NT1 and 120V AC adapter. |
| |
| P50-1SBRI | Pipeline 50 S/T BRI, requires external NT1. Includes 120V adapter. |
| |
| P50-1SBRI-ASA | Pipeline 50 S/T BRI with SecureConnect Firewall and 40-bit IPSec Encryption. Requires external NT1. |
| |
| P50-1UBRI | Pipeline 50 U BRI, includes NT1. Includes 120V adapter. |
| |
| P50-1UBRI-ASA | Pipeline 50 U BRI with SecureConnect Firewall and 40-bit IPSec Encryption. |
| |
| P50-LS56 | 4-Wire leased or switched 56k service. |
| |
| P50-LS56-2W | 2-Wire leased or switched 56k service. |
| |
| P50-1SBRI-X25 | Pipeline 50 with X.25 protocol pre-installed. |
| |
| P50-SWUP-P75 | Field Upgrade. Requires Serial Number 722xxxx and above on the Pipeline 50. |
| |
| PL-SWUP-563DES 3DES IPSec Upgrade | P50, 75 & 85 and SuperPipe 95 & 155 after-market upgrade for 128-bit IPSec Encryption (also includes 56-bit, 40-bit & AH only encryption). |
| |
| P50-PWR | 6-Pin old Pipeline 50 power supply. This is the original 6-Pin connector type P50/Multiband power supply. |
| |
| PL-PWR-A | Current (V2 Pipeline 50/75/85) power supply is PL-PWR-B. |
| |
| P75-1SBRI | Pipeline 75 S/T BRI interface (RJ-45). Requires external NT1. Includes 120V adapter. |
| |
| P75-1SBRI-ASA | Pipeline 75 S/T BRI with SecureConnect Firewall and 40-bit IPSec Encryption. |
| |
| P75-1UBRI | Pipeline 75 U BRI interface (RJ-48). Includes integrated NT1 for North America. |
| |
| P75-1UBRI-ASA | Pipeline 75 U BRI with SecureConnect Firewall and 40-bit IPSec Encryption. |
| |
| P75-1SBRI-X25 | Pipeline 75 with X.25 protocol pre-installed. |
| |
| PL-SWUP-563DES | P50, 75 & 85 and SuperPipe 95 & 155 after-market upgrade for 128-bit IPSec Encryption (also includes 56-bit, 40-bit & AH only encryption). |
| |
| PL-PWR-B | Interim P50/75/130 power supply is PL-PWR-A. |
| |
| P85-1SBRI | Pipeline 85 with S/T BRI interface. Requires external NT1. |
| |
| P85-1SBRI-ASA | Pipeline 85 S/T BRI with SecureConnect Firewall and 40-bit IPSec Encryption. |
| |
| P85-1UBRI | Pipeline 85 with U BRI interface. Includes integrated NT1. |
| |
| P85-1UBRI-ASA | Pipeline 85 U BRI with SecureConnect Firewall and 40-bit IPSec Encryption. |
| |
| P85-1SBRI-X25 | Pipeline 85 with X.25 protocol pre-installed. |
| |
| P130-SBRI-FT1 | This model requires an external NT1 for BRI operation. Includes an S/T interface. |
| |
| P130-UBRI-FT1 | This model includes an integrated CSU/DSU & NT1, U interface. Also supports AppleTalk routing. |
| |
| P130-FT1-ASA | Pipeline 130 U BRI with SecureConnect Firewall. |
| |
| P130-UBRI-L56 | This model includes an integrated 56k CSU & NT1. U interface. |
| |
| P130-L56-ASA | Pipeline 130 L56 with SecureConnect Firewall. Uses BRI connections and Leased Line. |
| |
| P130-SBRI-V35 | This model requires the P130-V35 cable for V.35 operation. Also Requires NT1 for ISDN operation. |
| |
| P130-S-V35-ASA | Pipeline 130 V.35 with SecureConnect Firewall. Requires NT1 for ISDN operation. |
| |
| P130-UBRI-V35 | ISDN BRI U interface. Note this model requires P130-V35 cable for V.35 operation. |
| |
| P130-U-V35-ASA | Pipeline 130 V.35 with SecureConnect Firewall. |
| |
| P22-T1-V35 | Pipeline 220 includes integrated T1 CSU/DSU |
| |
| P22-T1-V35-ASA | Pipeline 220 T1 with Secure connect Firewall and 40 bit |
| |
| P22-SWUP-563DES | Shrink wrapped separate box |
| |
| SP95-2U | SuperPipe 95 with dual U BRI interfaces. |
| |
| SP95-2S | SuperPipe 95 Router BRI-S. Universal power supply. |
| |
| SP155-T1-2U | SuperPipe 155 with T1 and dual U BRI interfaces. |
| |
| SP155-2S-T1 | SuperPipe 155 Router BRI-S with T1. Universal power supply |
| |
| SP155-2U-V35 | SuperPipe 155 Router BRI-U with V.35. Universal power supply. |
| |
| SP155-2S-V35 | SuperPipe 155 Router BRI-S with V.35. Universal power supply |
| |
| DSL PRODUCTS – DSL ACCESS CONCENTRATOR FAMILY |
| ||
| STGR MODEL | Stinger Base Unit, (1) Control Module. |
| |
| STGR-R MODEL | Stinger Base Unit, (2) Control Modules. |
| |
| STGR-LIM-AD-24 | Line Interface Modules - 24-Port ADSL-DMT Line Interface Module for ATM over ADSL-DMT. |
| |
| STGR-LIM-H2-32 | Line Interface Modules - 32-Port HDSL2 Line Interface Module for ATM over HDSL2. |
| |
| STGR-LIM-SH-48 | Inactive: Re-book as STGR-LIM-SQ-48. |
| |
| **STGR-LIM-SQ-48 | Line Interface Modules - 48-port SDSL Line Interface Module for SDSL. Supports operation at up to 2.3 Mbps per port. |
| |
| STGR-LIM-AD-12 | Refer to Sales Representative with request to re-book the required quantity of STGR-LIM-AD-24. |
| |
| STGR-TM-OC3-2 | 2-Port Trunk Module for operation at 155 Mbps per port over single-mode fiber. |
| |
| **STGR-TM-OC3-1 | 1-Port Trunk Module with OC-3/STM-1 interface (single mode, intermediate reach). Trunk Module for operation at 155 Mbps over single-mode fiber, at distances up to 20 km. 1310 nm Optical Transmit Power -14 dBm. Optical Receive Power -32.5 dBm to -8 dBm. |
| |
| **STGR-TM-OC3-2L | 2-Port Trunk Module with OC-3c/STM-1 interface (single mode, long reach). Trunk Module for operation at 155 Mbps per port over single-mode fiber, at distances up to 40 km. 1310 nm Optical Transmit Power -5 dBm. Optical Receive Power -34 dBm to -3 dBm. |
| |
| **STGR-TM-OC3-1L | 1-Port Trunk Module with OC-3c/STM-1 interface (single mode, long reach). Trunk Module for operation at 155 Mbps over single-mode fiber, at distances up to 40 km. 1310 nm Optical Transmit Power -5 dBm. Optical Receive Power -34 dBm to -3 dBm. |
| |
| **STGR-TM-OC3-2M | 2-Port Trunk Module with OC-3c/STM-1 interface (multi-mode). For operation at 155 Mbps per port over multi-mode fiber, at distances up to 2 km. 1300 nm Optical Transmit Power -19 dBm (62.5/125um fiber). Optical Receive Power -31 dBm to -14 dBm. |
| |
| **STGR-TM-OC3-1M | 1-Port Trunk Module with OC-3c/STM-1 interface (multi-mode). Trunk Module for operation at 155 Mbps over multi-mode fiber, at distances up to 2 km. 1300 nm Optical Transmit Power -19 dBm (62.5/125um fiber). Optical Receive Power -31 dBm to -14 dBm. |
| |
| STGR-TM-DS3-2 | 2-Port Trunk Module for operation at 44.736 Mbps per port. |
| |
| **STGR-TM-DS3-1 | 1-Port Trunk Module with DS-3 interface (coax). Trunk Module for operation at 44.736 Mbps. |
| |
| STGR-LPM-48-RP | 48-Port LPM with Port Redundancy. Line Protection Module with (2) 50-Pin telco connectors. Each connector supports 24-Ports (2 wires per port). Provides electrical isolation and surge protection. |
| |
| STGR-LPM-48 | 48-Port LPM. Line Protection Module with (2) 50-Pin telco connectors. Each connector supports 24-Ports (2 wires per port). Provides electrical isolation and surge protection. |
| |
| STGR-LPM-24-RP | 24-Port LPM with Port Redundancy. Line Protection Module with (1) 50-Pin telco connector. Each connector supports 24-Ports (2 wires per port). Provides electrical isolation and surge protection. |
| |
| STGR-LPM-24 | 24-Port LPM. Line Protection Module with (1) 50-Pin telco connectors. Each connector supports 24-Ports (2 wires per port). Provides electrical isolation and surge protection. |
| |
| STGR-IRM-S | Interface Redundancy Module for single redundancy slot. |
| |
| STGR-PSM | Path Selector Module. Provides access for an external copper loop tester to any subscriber line attached to the Stinger. |
| |
| STGR-CLT | Integrated Copper Loop Test Module. Enables remotely controlled loop qualification and maintenance for any subscriber line attached to the Stinger. This module comprises the Path Selector Module plus an integrated test head. |
| |
| STGR-CABMGT | Cable Management Kit. |
| |
| STGR-SP-CM | Stinger Control Module. |
| |
| STGR-SP-AR | Stinger Alarm Relay. |
| |
| STGR-SP-DCTRAY | Stinger DC Filter Tray. |
| |
| STGR-SP-FAN | Stinger Cooling System. |
| |
| STGR-RM23 | Stinger 23-Inch Rack Mount Kit. |
| |
| STGR-RM19 | Stinger 19-Inch Rack Mount Kit. |
| |
| DSLTNT-AC-H | DSLTNT Base Chassis with High Output AC Power Supply and Controller Card. |
| |
| DSLTNT-DC-H | DSLTNT Base Chassis with High Output DC Power Supply and Controller Card. |
| |
| DSLMX20-AC | DSLMAX 20 Chassis, AC. |
| |
| DSLMX20-DC | DSLMAX 20 Chassis, DC. |
| |
| DSLMX20-2DC | DSL MAX 20 Chassis with redundant DC Power Supply. |
| |
| DSLMX20-AC8 | DSL MAX 20 8-User MTU/MDU Starter Kit, T1 - AC version. |
| |
| DSLMX20-AC16 | DSL MAX 20 16-User MTU/MDU Starter Kit, T1 - AC version. |
| |
| DSLMX20-DC8 | DSL MAX 20 8-User MTU/MDU Starter Kit, T1 - DC version. |
| |
| DSLMX20-DC16 | DSL MAX 20 16-User MTU/MDU Starter Kit, T1 - DC version. |
| |
| DMX-SL-SDSLH8 | Slot card for DSLMAX 20, 8-Port 2.3 Mbps SDSL. |
| |
| DMX-SL-SDSLH16 | Slot card for DSLMAX 20, 16-Port 2.3 Mbps SDSL. |
| |
| DMX-SL-T1 | Slot card for DSLMAX 20/DSLTerminator 100/cvMAX 100. 4-Port T1 interface, unchannelized. |
| |
| DMX-SL-E1 | Slot card for DSLMAX 20/DSLTerminator 100/cvMAX 100. 4-Port E1 interface, unchannelized. |
| |
| DMX-SL-DS3ATM | Slot card for DSLMAX 20, DSLTerminator 100, Single port DS-3 ATM. |
| |
| DMX-SL-DS3FR | Slot card for DSLMAX 20/DSLTerminator 100, Single port DS-3 Frame Relay. |
| |
| DMX-SL-OC3A | Slot Card ATM/STM-1 OC-3 Opt 1Mode |
| |
| DMX-SO-8T1 | Upgrade from 4-Port T1 to 8-Port T1. |
| |
| DMX-SO-8E1 | Upgrade from 4-Port E1 to 8-Port E1. |
| |
| DSLTR100-AC | DSI Terminator 100 chassis, 2slot, 2 ethernet port ac version |
| |
| DSLTR100-DC | DSLTerminator 100 Chassis, (2) Slots, (2) Ethernet ports, DC version. |
| |
| DSLTR100-2DC | DSLTerminator 100 Chassis, Redundant DC Power Supply. |
| |
| DSLTR100-SP-VPN | VPN Option for the DSL Terminator 100. |
| |
| Page 1 of 5 [ Next Page ] | |||
Catalog current as of Wed Nov 11 13:04:06 2009



